Test Tools

  • Beam Alignment Test Tool
    Beam Alignment Test Tool
      The Beam Alignment Test Tool Model 162A provides a simple test of the x-ray beam alignment. When used with the Collimator Test Tool, X-ray beam misalignments of 1 and 2% can be visualized without the need for...
    View Details
  • Collimator Test Tool
    Collimator Test Tool
      Evaluate collimator light field and x-ray field congruence plus ensure accurate x-ray beam alignment The Gammex 161B Collimator Test Tool is designed to evaluate the collimator light field and x-ray field congruence...
    View Details
  • Collimator/Beam Alignment Test Tool
    Collimator/Beam Alignment Test Tool
    Test Device Set LiRa (Collimator / Beam Alignment Test Tool) Verification of the proper alignment of the collimator light field with the X-ray field Verification of the central beam alignment (perpendicular to the image...
    View Details
  • Computed and Digital Radiography Commissioning QA Phantom Set
    Computed and Digital Radiography Commissioning QA Phantom Set
    A set of test objects designed to be used quickly and easily on a annual / commissioning basis to provide an ongoing check of imaging performance, particularly those aspects which are most liable to deterioration...
    View Details
  • Copper HVL Attenuator Set
    Copper HVL Attenuator Set
      Gammex Model 116 For Radiation energies of 140 to 400 kVp, copper is used for specifying the half value layer of the x-ray beam. The 116 RMI provides a pure copper HVL set which includes nine sheets of 10x10cm...
    View Details
  • Digital cardiac/digital spot imaging
    Digital cardiac/digital spot imaging
    These test objects are designed for quick quantitative assessments of image quality. The results can be plotted on a Threshold Detection Index Curve. TO 12 Digital Spot Imaging systems. A range of 9 contrasts per detail...
    View Details
  • Film/Screen contact Test Tool,  Wire Mesh
    Film/Screen contact Test Tool, Wire Mesh
      Good film-screen contact across the entire area of the screen is needed for quality diagnosis.  Routine testing of all of the cassettes in the department detects areas of poor film-screen contact as part of the...
    View Details
  • Film/Screen Contact Test Tool, Perforated Brass
    Film/Screen Contact Test Tool, Perforated Brass
      Good film-screen contact across the entire area of the screen is needed for quality diagnosis.  Routine testing of all of the cassettes in the department detects areas of poor film-screen contact as part of...
    View Details
  • Fluoroscopy Step Wedge
    Fluoroscopy Step Wedge
    11 Step Wedge for use with Fluoroscopy systems. Material: Aluminium Overall dimensions: 132 x 50 x 35mm Steps 12mm long x 50mm wide Step 1: 5mm high Other Steps: 3mm...
    View Details
  • Focal Spot Test Tool
    Focal Spot Test Tool
      The focal spot size of an X-ray tube is a key factor in determining system resolution.  The smaller the focal spot size, the sharper the image at  high geometric magnification.  The Gammex 112B Focal...
    View Details
  • Grid Alignment Test Tool
    Grid Alignment Test Tool
      Improves alignment of the radiographic grid and central ray of the x-ray tube and provides increased image contrast, improved shading in image density, and can reduce unnecessarily increased patient dosage...
    View Details
  • High Contrast Resolution Test Tool
    High Contrast Resolution Test Tool
      An important measure of your fluoroscopy system is its high contrast resolution.  This test is used to assess the resolving power of your system and can be done easily with the Gammex 141 and 141H High...
    View Details
  • HVL Attenuator Set
    HVL Attenuator Set
    Half Value Layer Attenuator Set The Gammex 115A Half Value Layer Attenuator Set is designed to be used to determine the Half Value Layer (HVL) of the x-ray beam to specify the quality of the x-ray beam. For a given kVp, a...
    View Details
  • Light Field Ruler
    Light Field Ruler
      This tool is a tool to measure the coincidence of the light and radiation fields of analog or digital flat plate/film X-ray units including mammography systems. The unit consists of the body which houses a strip of...
    View Details
  • Medical Display Calibration Software Kit
    Medical Display Calibration Software Kit
    This complete Medical Display Calibration Software Kit includes SpectraCal CalMED+ Medical Display Calibration Software & SpectraCal C6 Colorimeter CalMED+ is the medical display calibration software that...
    View Details
  • Rad Aluminum Stepwedge
    Rad Aluminum Stepwedge
      The aluminum stepwedge is the standard tool for evaluating the dynamic range (latitude) of a digital or film-screen imaging system.  This wedge provides 11 steps in 3.2 mm increments.  The number of...
    View Details
  • Radiopaque Light Field Centering Ruler
    Radiopaque Light Field Centering Ruler
    This is a set of 400mm '0' center rulers on a center aluminum pin. The center is designed to easily read all 200 graduations in all directions from center, with no graduation overlap. The set swings open for use and closes...
    View Details
  • Routine QA Phantom - PIX 13
    Routine QA Phantom - PIX 13
    Leeds Test Objects’ PIX-13 phantom is designed to be used to check the image quality performance of digital radiography x-ray systems. These tests should be carried out at acceptance to establish a baseline, and on...
    View Details
  • Set of four test objects -DSF Set
    Set of four test objects -DSF Set
    A set of four test objects, the DSF set is supplementary to the SFS set of test objects and checks those parameters which are particularly relevant to DSF imaging. After mask images have been obtained the image content is...
    View Details
  • Slit Camera for X-ray focal spot measurements
    Slit Camera for X-ray focal spot measurements
    Focal Spot Measurements The RTI Slit Camera for X-ray focal spot measurements, to assure that the tube and X-ray tube focal spot size is within acceptable limits. The Slit Camera can be rotated 90 degrees in the Slit Camera...
    View Details
  • Test object for Digital Spot Imaging / Digital Cardiac Imaging Systems. TO DR
    Test object for Digital Spot Imaging / Digital Cardiac Imaging Systems. TO DR
    These test objects are designed for systems which operate by sensing mean signal levels, the TO DR tests dynamic range by measuring detail visibility over a wide range of input X-ray intensities. Different designs cater for...
    View Details
  • Test object, Threshold-contrast detail-detectability - TO 20
    Test object, Threshold-contrast detail-detectability - TO 20
    These test objects are designed for quick quantitative assessments of image quality. The results can be plotted on a Threshold Detection Index Curve. TO 20 Digital Subtraction Fluoroscopy. A range of 12 contrasts per...
    View Details
  • TFG Ruler
    TFG Ruler
    Create Permanent alignment Record   Confirmation of alignment between laser lights and the X-ray energy field is a routine QA check. Although there is equipment available, they do not provide a permanent record of the...
    View Details
  • Threshold-contrast detail-detectability -TO 10
    Threshold-contrast detail-detectability -TO 10
    These test objects are designed for quick quantitative assessments of image quality. The results can be plotted on a Threshold Detection Index Curve. TO 10 Fluoroscopic X-Ray systems. A range of 9 contrasts per detail...
    View Details
  • Threshold-contrast detail-detectability: TO 16
    Threshold-contrast detail-detectability: TO 16
    These test objects are designed for quick quantitative assessments of image quality. The results can be plotted on a Threshold Detection Index Curve. TO 16 Computed Digital Radiography. A range of 12 contrasts per detail...
    View Details
  • Tomographic Test Tool
    Tomographic Test Tool
      The Gammex 132 Tomographic Test Tool is designed to test the imaging capabilities of the tomographic X-ray system Used in conjunction with other Gammex test instruments for measuring radiation output (i.e., kV...
    View Details
  • TOR CDR - Routine Test Object for conventional and non-subtractive digital radiography.
    TOR CDR - Routine Test Object for conventional and non-subtractive digital radiography.
    TOR CDR radiography phantom is a routine test object designed to be used quickly and easily on a regular basis (e.g. weekly or monthly) to provide an ongoing check of imaging performance, particularly those aspects...
    View Details
  • TOR MAM - Supplemental Test Object for TOR-MAS
    TOR MAM - Supplemental Test Object for TOR-MAS
    TOR MAM mammography phantom is designed to be used quickly and easily on a routine basis to provide an ongoing check of imaging performance, particularly those aspects which are most liable to deterioration. An ongoing...
    View Details
  • Tungsten Edge Test Tool - TO MTF
    Tungsten Edge Test Tool - TO MTF
    An MTF Edge test device comprising an angulation wheel and a Tungsten edge. Features: 1mm thick Tungsten plate (50mm diameter) Tungsten purity of 90%+ Edge accuracy of 5μm Repeatable angular adjustment Conforms...
    View Details
  • Universal Test Stand
    Universal Test Stand
      The Gammex 175 Universal Test Stand can be used to perform a variety of quality control tests for mammographic and radiographic x-ray systems. The height of the tower is easy to adjust and the cassette holder...
    View Details
  • VISI-X Field Position Analyser
    VISI-X Field Position Analyser
      The Visi-X is a proven concept in Quality Control and Service. It is a cassette shaped instrument for checking the light and radiation field coincidence on X-ray equipment. The Visi-X can also be used for checking of...
    View Details
  • X-ray Test Patterns
    X-ray Test Patterns
    X-ray Test Patterns for Measuring Resolution The choice of pattern depends on the specific application. The sector test patterns are 0.4 degree and the group test patterns have varying numbers of line pair groups. Lead...
    View Details