LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector

  • LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector
  • LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector
  • LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector
  • LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector
  • LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector
  • LB 124 SCINT-D - Contamination Monitor with Dose Rate Detector

Description

The Contamination Monitor with Dose Rate Detector LB 124 SCINT-D is used to measure radioactive alpha and beta-gamma contaminations on surfaces such as floors, walls, desks, objects, clothing or skin as well as gamma dose rate in ambient dose rate equivalent H*(10).

The Contamination Monitor LB 124 SCINT-D is a portable battery-powered instrument. It is comprised of a display unit with microprocessor electronics, a signal processing electronics and a new type of ZnS-scintillator with photomultiplier and an active measurement area of 170 cm². Its sophisticated reflector geometry ensures an extremely flat response over the entire sensitive area.

Through the integration of an additional Geiger-Müller tube it is possible to measure gamma dose rate simultaneous besides regular contamination measurement.

Due to its attractive and ergonomic design and its low weight the LB 124 SCINT-D is easy to handle. Even under adverse conditions, the measured results can be read easily on the large-highly-resolution display with background lightning.

A few directly accessible function keys suffice to operate the LB 124 SCINT-D. The instrument´s surface can be easily decontaminated.

Highlights:

  • Lightweight, easy to handle and rugged instrument
  • Wide temperature range 

Contamination Detector

  • Simultaneous and separate measurement of alpha and beta-gamma contamination with a ZnS(Ag)-scintillation detector
  • High sensitivity and uniform response
  • No counting gas required 

Dose Rate Detector

  • Detector positioned parallel to the front side of the instrument
  • Energy response to H*(10) Ambient Dose Equivalent
  • Halogen quenched Geiger-Müller tube
  • Dynamic Range: 0.1 μSv/h to 20 mSv/h
  • Energy Range: 50 keV to 1.3 MeV
  • Alarm threshold for dose rate measurement
  • Unit selection: μSv/h
  • Dose accumulation is possible

Additional Product Specifications available upon request.